★ Pass on Your First TRY ★ 100% Money Back Guarantee ★ Realistic Practice Exam Questions
Free Instant Download NEW NS0-520 Exam Dumps (PDF & VCE):
Available on:
https://www.certleader.com/NS0-520-dumps.html
Ucertify offers free demo for NS0-520 exam. "NetApp Certified Implementation Engineer - SAN. ONTAP", also known as NS0-520 exam, is a Network-Appliance Certification. This set of posts, Passing the Network-Appliance NS0-520 exam, will help you answer those questions. The NS0-520 Questions & Answers covers all the knowledge points of the real exam. 100% real Network-Appliance NS0-520 exams and revised by experts!
Network-Appliance NS0-520 Free Dumps Questions Online, Read and Test Now.
NEW QUESTION 1
Exhibit.
Referring to the exhibit, which type of zoning should be used?
- A. a WWPN with a single initiator and multiple targets
- B. a WWPN with a single initiator and a single target
- C. a WWNN with a single initiator and multiple targets
- D. a WWNN with a single Initiator and a single target
Answer: B
NEW QUESTION 2
Click the Exhibit button.
You have a 2-node cluster in a single-fabric SAN. Host 1 and Host 2 are part of a VMware cluster and access the same LUNs that reside in your NetApp storage.
Referring to the exhibit, what would be a way to test whether the multipathing is properly configured in your environment?
- A. Verify whether all destination storage target ports are contained in the same zone as Host 1.
- B. Administratively set ports 0a and 0c on Controller 1 to the offline setting.
- C. Power off the SAN switch.
- D. Disconnect Host 1 port and verify whether Host 2 is still able to run the VMs.
Answer: B
NEW QUESTION 3
A customer wants to use both Cisco FC and FCoE switches in their ONTAP environment. According to NetApp best practices, what are two requirements in this scenario? (Choose two.)
- A. You must use single initiator zoning.
- B. You must create interface groups to isolate FC and FCoE LIFs.
- C. You must create a trunk with multiple virtual LANs.
- D. You must not have more than one target UF for the same physical port in a single fabric zone.
Answer: AD
NEW QUESTION 4
Exhibit.
A customer is testing a dual-fabric FC SAN configuration as shown in the exhibit and the zones are implemented on the switches shown below.
If all the nodes are in the SLM reporting nodes list, hoe many path per LUN should the customer expect when simulating an FC SFP failure by bringing LIF_3 offline?
- A. 15 paths
- B. 3 paths
- C. 4 paths
- D. 7 paths
Answer: D
NEW QUESTION 5
Which option needs to be set on a LUN to guarantee that it cannot be affected by other LUNs in the volume?
- A. Volume Guarantee
- B. Volume Space Reserved
- C. LUN Reservation Disabled
- D. LUN Reservation Enabled
Answer: D
NEW QUESTION 6
Your customer asks you how to connect a host for SAN access to the newly installed AFF A400 system. In this scenario, which two statements are correct? (choose two)
- A. Direct Connection to the nodes from the hosts with ISCSI is supported
- B. Direct Connection to the nodes from the hosts with ISCSI is not supported
- C. Direct Connection to the nodes from the hosts with FC is not supported
- D. Direct Connection to the nodes from the hosts with FC is supported
Answer: AC
Explanation:
ISCSI-Direct-attachment: In a direct-attached configuration, one or more hosts are directly connected to the controllers.
You cannot directly attach FC or FC-NMVE SAN hosts to single nodes without using an FC switch. You can find more information on this link:
https://docs.netapp.com/ontap-9/index.jsp?topic=%2Fcom.netapp.doc.dot-cm-sanconf%2FGUID-193CC377-5C
NEW QUESTION 7
You have a 4-node cluster with a FAS8200 HA pair and an AFF A300 HA pair. You need to migrate a LUN from a FAS8200 node to an AFF A300 node for faster performance.
Which method will non-disruptively migrate the LUN to the AFF A300 while retaining snapshots of the LUN on the FAS8200?
- A. You move the LUN.
- B. You relocate the aggregate.
- C. You move the volume.
- D. You copy the LUN.
Answer: D
NEW QUESTION 8
You are installing an AFF A250 system with ONTAP 9.8 software. Your customer asks you about the recommended LIF configuration for the ISCSI protocol. In this scenario, which two statements are correct
(choose two)
- A. Each node in an ISCSI configuration must be connected to a minimum of two ethernet switches
- B. All LIFs from the SVM are connected to a single Ethernet switch
- C. Each SVM in an ISCSI configuration must have a minimum of two LIFs per node
- D. Each SVM in an ISCSI configuration must have a minimum of one LIF per node
Answer: AC
Explanation:
It is recommended that all SVMs in ISCSI configurations have a minimum of two LIF's per node in separate Ethernet networks for redundancy and MPIO across multiple paths.
You can find more information on this link:
https://docs.netapp.com/ontap-9/index.jsp?topic=%2Fcom.netapp.doc.dot-cm-sanconf%2FGUID-650DC466-CA
NEW QUESTION 9
You want to provision an iSCSl LUN.
Which two steps are required to accomplish this task? (Choose two.)
- A. Add the initiator IP address to the igroup.
- B. Map the LUN to the igroup.
- C. Add the target WWPN to the igroup.
- D. Add the initiator 1QN to th«t igroup.
Answer: BD
NEW QUESTION 10
Which two components must be verified for a supported NetApp SAN confutation? (Choose two.)
- A. host memory
- B. host GPU
- C. host multipath
- D. host bus adapter
Answer: CD
NEW QUESTION 11
You are configuring a VMware sphere host for FC access to a Netapp ONTAP cluster. In this scenario, which two tasks does Netapp recommend performing on the Vsphere host? (choose two)
- A. Set the queue depth on the host to 8
- B. Update the HBA driver
- C. Zone the host by using the host WWNNs
- D. Use the Netapp Virtual Storage Console to configure the host settings
Answer: BD
Explanation:
Zoning the host using WWNNs is not recommended. Netapp always recommends to use WWPN to zone correctly.
We can not stablish a queue depth value because we don't have the amount of ports and hosts to calculate the recommended queue depth
Installing VSC and updating the HBA driver are best practices recommended by Netapp
You can find more information on this link:
https://docs.netapp.com/ontap-9/index.jsp?topic=%2Fcom.netapp.doc.exp-iscsi-esx-cpg%2FGUID-C751F905-0 https://docs.netapp.com/ontap-9/topic/com.netapp.doc.exp-fc-esx-cpg/FC%20express%20configuration%20for%
(page 7)
NEW QUESTION 12
An administrator is asked to provision a SAN environment in which host applications can monitor LUN space and performance space reclamation.
Which LUN type would satisfy these requirements?
- A. SCSI thick provisioned LUN
- B. SCSI thin provisioned LUN
- C. NetApp thin provisioned volume
- D. NetApp thick provisioned volume
Answer: B
Explanation:
Automatic host-side space management with SCSI thinly provisioned LUNs
If your host supports SCSI thin provisioning, you can enable the space-allocation option in ONTAP to turn on automatic host-side space management.
You can find more information on this link:
https://docs.netapp.com/ontap-9/index.jsp?topic=%2Fcom.netapp.doc.dot-cm-sanag%2FGUID-93D78975-6911
NEW QUESTION 13
You want configure namespaces to support NVMe over Fibre Channel (NVMe/FC) using ONTAP 9.8. Which action will accomplish this task?
- A. Add FC to the list of SVM protocols
- B. Remove any protocols from the SVM before adding the NVMe protocol
- C. Enable ALUA on the namespaces that should use the NVMe protocol
- D. Configure a LIF for the NVMe protocol
Answer: D
Explanation:
Although ONTAP uses a NVMe/FC LIF that is separate from the FCP LIFs, both LIFs can be hosted on the same physical HBA port at both the host initiator and storage target. NVMe/FC and FCP can
share the same physical infrastructure concurrently, so the same physical port, cable, switch port, and target port can simultaneously host and transmit both FCP and NVMe/FC frames
NVMe can use the same FC infraestructure, but it needs to create a separate NVMe LIF to work. You can find more information on this link:
https://www.netapp.com/de/media/10681-tr4684.pdf (14)
NEW QUESTION 14
An administrator enabled the FCP protocol on an SVM and created a boot LUN for a Windows Server 2019 server host. The host is attached using multiple paths to the storage SVM. After correctly adding
the LUN to the igroup and setting its LUN ID to 1, the host is unable to boot using the installed FC HBA.
- A. The LUN ID must be set to 0
- B. The LUN ID must be set to 255
- C. During the boot process, using FCP is not supported by Netapp
- D. During the boot process, using FCP is not supported by Microsoft
Answer: A
Explanation:
Create the LUN that you want to use as a boot device, and map it to the igroup as LUN ID 0 You can find more information on this link:
https://library.netapp.com/ecmdocs/ECMP1656701/html/GUID-76BFD6AC-BC2A-419A-9DD3-D98423B2B6
NEW QUESTION 15
An administrator is asked to configure NVMe on an ONTAP 9.5 cluster for host access. Which three steps must the administrator perform to accomplish this task? (Choose three.)
- A. Create a namespace.
- B. Provision a subsystem.
- C. Configure the FC port.
- D. Gather the IQN from the host initiator software.
- E. Gather the NQN from the host system.
Answer: ABE
Explanation:
Reference: https://thinksystem.lenovofiles.com/storage/help/topic/san_administration_guide/M_DDA6B457- 8544-43AC-92E8-D846A0BA7671_.pdf (26)
NEW QUESTION 16
What is the default Ethernet packet size (or MTU - Maximum Transmission Unit) for Ethernet ports on Ethernet switches?
- A. 2112 bytes
- B. 9000 bytes
- C. 1500 bytes
- D. 12000 bytes
Answer: C
NEW QUESTION 17
Exhibit.
An administrator is configuring FCoE on Cisco Nexus switches for a new AFF A200 ONTAP cluster. The administrator executes the commands shown in the exhibit to create the necessary network configuration.
Which VLAN is responsible for controlling the FCoE traffic on the new interface?
- A. 3011
- B. 23
- C. 11
Answer: B
NEW QUESTION 18
......
Thanks for reading the newest NS0-520 exam dumps! We recommend you to try the PREMIUM Dumps-files.com NS0-520 dumps in VCE and PDF here: https://www.dumps-files.com/files/NS0-520/ (234 Q&As Dumps)