Want to know Actualtests NS0-592 Exam practice test features? Want to lear more about Network-Appliance NetApp Certified Support Engineer - ONTAP Specialist certification experience? Study Virtual Network-Appliance NS0-592 answers to Abreast of the times NS0-592 questions at Actualtests. Gat a success with an absolute guarantee to pass Network-Appliance NS0-592 (NetApp Certified Support Engineer - ONTAP Specialist) test on your first attempt.
Free demo questions for Network-Appliance NS0-592 Exam Dumps Below:
NEW QUESTION 1
A customer reports that copying data over iSCSI attached LUNs is taking significantly longer than usual. The customer asks you to help to identify the root cause of this problem.
Which two perfstat sections would you use to accomplish this task? (Choose two.)
- A. stats lun
- B. lun stats -vserver
- C. statit
- D. stats volume
Answer: BC
NEW QUESTION 2
Click the exhibit button.
Your customer is calling about their MetroCluster environment. They have provided you with the output of the metrocluster interconnect adapter show command.
Referring to the exhibit, which statement is correct?
- A. For all MetroCluster configurations, this is expected output.
- B. The InfiniBand cables should be connected in this configuration.
- C. The InfiniBand interconnect is not used in MetroCluster.
- D. This is a 2-node MetroCluster.
Answer: A
NEW QUESTION 3
Click the exhibit button.
A customer is reporting that numbers in the statistics volume show command output appear to be incorrect. Referring to the exhibit, which statement is correct?
- A. The problem is due to a difference in operation size.
- B. Perfstat should be used to explain the behavior.
- C. There are operation types that are not listed in the output.
- D. A case with NetApp should be raised to find the root cause.
Answer: A
NEW QUESTION 4
Click the exhibit button.
A customer reports that their system recently began logging an error. Referring to the exhibit, which two statements are correct? (Choose two.)
- A. The bcomd application is responsible for monitoring the observed behavior.
- B. A user is attempting to restart the ntpd daemon.
- C. The spmd application failed to restart the ntpd daemon.
- D. The ntpd daemon is responsible for time services.
Answer: BD
NEW QUESTION 5
Click the exhibit button.
A customer reports that storage latency has recently increased substantially. No changes have been introduced, and the traffic did not change.
Referring to the output shown in the exhibit, which corrective step should be taken?
- A. Add more spindles.
- B. Throttle the client traffic.
- C. Perform the volume reallocation.
- D. Move some volumes off the affected aggregate.
Answer: B
NEW QUESTION 6
Click the exhibit button.
A customer has an FC SAN with brocade switches. Each server attached to the SAN gas four FC ports. The customer describes that one of their servers has only four paths to the LUNs configured on the cluster. There should be eight paths on all the other servers. The switch administrator has verified the zone configuration.
Referring to the exhibit, which two actions would you perform to troubleshoot the problem? (Choose two.)
- A. Review the LIF configuration on the cluster.
- B. Review the driver version on the server.
- C. Review that the host side FC link ports are enabled.
- D. Review the igroup configuration on the cluster.
Answer: AB
NEW QUESTION 7
Click the exhibit button.
Your customer added a new DS4246 shelf to their FAS system. They created an aggregate on the new shelf. Two weeks later, they log in to Active IQ and discover the Medium Impact error shown below.
“Both SAS connections from one controller go to the same shelf.” Referring to the exhibit, which statement is correct?
- A. You are unable to obtain a “Cable Visualization” overview from Active IQ.
- B. A faulty cable is causing the problem.
- C. A faulty IOM is causing the problem.
- D. You can correct this problem without downtime on the FAS system.
Answer: D
NEW QUESTION 8
A customer reports that OnCommand Performance Manager shows that the workload on node-02 in a 4-node cluster has increased to a level that is higher than the threshold. The customer wants to avoid this issue becoming a performance problem.
Which two actions would result in achieving this goal? (Choose two.)
- A. Use the volume move command to move one or more volumes to another aggregate that is owned by another node that is less utilized.
- B. Use the storage aggregate relocation command to offload an aggregate to its partner.
- C. Use the storage aggregate scrub command to verify the parity on the busy aggregates.
- D. Physically move the shelf to another node that is less utilized.
Answer: AD
NEW QUESTION 9
Click the exhibit button.
A customer has the ns-switch shown in the exhibit.
Which two statements are true in this scenario? (Choose two.)
- A. User names not present in the local database are looked up in LDAP.
- B. User mapping decisions are always based on the LDAP configuration.
- C. Host names are always resolved using the configured DNS server.
- D. Groups can be looked up both in the local database and in LDAP.
Answer: CD
NEW QUESTION 10
A customer has created an interface group (igroup) named a0a, a VLAN named a0a-2500, and a data LIF associated with the VLAN interface that has been assigned an IP of 10.254.10.100. The customer is able to ping 10.254.10.100 from a Windows client without any issues, but data traffic is not working.
In this scenario, what is the solution to the problem?
- A. Disable flow control on the a0a interface.
- B. Configure an appropriate service policy for the data LIF.
- C. Correct the MTU mismatch between the broadcast domain configuration and the upstream network switches.
- D. Allow data traffic by using LIF firewall policies.
Answer: D
NEW QUESTION 11
A customer has a 2-node MetroCluster. They experienced a complete power loss at site B. The customer has lost connectivity to site B and now realizes that the DR partner at site A has not taken over the DR partner at site B.
Which two actions must be performed in this scenario? (Choose two.)
- A. On the DR partner at site A, perform the process to switchover.
- B. Ensure that site B is prevented from serving data or simply powered off (nodes and disk shelves).
- C. On the DR partner at site A, perform the process to heal the data aggregates.
- D. On the DR partner at site B, perform the process to heal the root aggregate.
Answer: AD
NEW QUESTION 12
Click the exhibit button.
Your customer reports that their FAS2554A system reports multi-path HA when running the sysconfig command. However, Config Advisor reports an error about incorrect cabling.
What are the two reasons for the messages? (Choose two.)
- A. Shelves 10 and 20 have different IOM modules and must be in separate stacks.
- B. The FAS2554 system is cabled incorrectly to shelf ID 20.
- C. The DS2246 shelf is wrong; the shelf ID must be 11.
- D. Disk shelves 10 and 20 are cabled incorrectly to each other.
Answer: BD
NEW QUESTION 13
You configured iSCSI multipathing on a Windows host to a 2-node ONTAP cluster so that you can attach to some LUNs. You see that the host logging in to both iSCSI LIFs in the ONTAP cluster, and you notice that the igroup is correctly set. After you open Disk Management and rescan for disks, the NetApp LUNs do not show up.
In this scenario, what should be performed to enable the LUNs to be visible to the Windows host?
- A. Set up LUN mapping and try scanning again.
- B. Configure the SVM for FCP and try scanning again.
- C. Set up Selective LUN Mapping (SLM) and try scanning again.
- D. Configure the ONTAP nodes for HA and try scanning again.
Answer: C
NEW QUESTION 14
A customer’s FAS8200 node1 went down an hour ago after a WAFL inconsistency error. All data is being served from partner node2, but the storage failover show command output is not showing a node1 as “Waiting for giveback”.
What is the corrective action for this situation?
- A. Re-create the root aggregate on node1.
- B. Boot the system and run the wafliron command on the inconsistent data aggregate.
- C. From the LOADER prompt, run the wafliron command on the system’s root aggregate.
- D. Boot the system and run the WAFL_check command on the inconsistent data aggregate.
Answer: A
NEW QUESTION 15
The root aggregate on your single-node ONTAP cluster failed. You have the configuration backups saved on your FTP server?
In this scenario, which two steps are part of the recovery procedure? (Choose two.)
- A. Perform a Netboot using the configuration backup.
- B. Create a new aggregate and set its ha_policy option to sfo.
- C. Boot into maintenance mode.
- D. Create a new root aggregate and set its ha_policy option to cfo.
Answer: CD
NEW QUESTION 16
Your customer states that the storage efficiency on their FAS 8200 is far below what they had expected for a VMware NFS datastore. They enabled deduplication three days ago. The job ran every night for only 10-20 minutes, and the space savings now is less than 5%.
What is causing the space savings to be so low?
- A. They have enabled aggregate-level inline data compaction, so the savings are at the aggregate level.
- B. They have enabled aggregate-level inline deduplication, so the savings are at the aggregate level.
- C. They have not enabled volume-level compression.
- D. They have not run a baseline deduplication to scan old data.
Answer: C
NEW QUESTION 17
An administrator wants to keep an automatic daily up-to-date copy of a volume at a disaster recovery location. What should the administrator do to achieve this goal?
- A. Perform a volume relocation to the remote location.
- B. Configure a SnapMirror relationship to the remote location.
- C. Configure a SyncMirror relationship to the remote location.
- D. Perform an NDMP dump to the remote location.
Answer: B
NEW QUESTION 18
Click the exhibit button.
A customer’s system reported several errors. There was no disruption, but the customer is concerned about the system’s health.
Referring to the exhibit, which statement is true?
- A. One of the switches has failed.
- B. One of the IOM modules on shelf 20 has failed.
- C. Storage redundancy is degraded.
- D. Port 1D on the system has failed.
Answer: C
NEW QUESTION 19
......
100% Valid and Newest Version NS0-592 Questions & Answers shared by Downloadfreepdf.net, Get Full Dumps HERE: https://www.downloadfreepdf.net/NS0-592-pdf-download.html (New 65 Q&As)